HHD 2019 CATALOG
Transfer Pumps 500 Series
Our smaller, 3-chamber 5800 Series pumps are designed for intermittent duty, thoughmostmodels canbe run continuously for hours at a time.These pumps are commonly used either topressurizewater froman atmospheric tank, todeliver purifiedwater to a specific point of use, or simply to increase pressurewhen required. These pumps can either be controlled by a pressure switch (“demand”mode) or an external power control device (“delivery”mode). When required, an integrated bypass can be incorporated to help regulate pressure levels. TYPICAL APPLICATIONS: Water Vending Agricultural Spraying(*) General Industrial Alternative Energy/Solar
Technical
Specifications
Mounting:
Power: Available motors from 12VDC to 230VAC, energy requirements between 50W-200W (depending on flow, pressure). Can be used with compatible
All positions, Standard offering is a steel mounting base with four hollow rubber grommets.
transformers and/or DC power supplies, to be ordered separately. Standard terminations are 12”, stripped end AWG leadwires, with connectors and power cords also available
Control Options:
Internal Bypass (20-100 psi), Pressure Switch (40-70 psi)
Fittings:
Pumphead options include 3/4”openings (for use with 3/8”, 5/8”, 1/2”, 3/4”hose barb, quick connect fittings), and 1/2”NPT female ports, and John Guest 1/2” and 3/8”fittings.
Envelope Dimensions:
Approximately 4” x 5” x 8”, weighs 8lbs
Delivery/
Transfer Pumps
Part No.
MFG.
FITTING
SHUT-OFF PRESSURE (PSI)
ELECTRICAL
NOTATIONS
CASE PK
F5852-7F12-J604
Aquatech
3/8”JG
70
115V
W/CORD 1.4 GPM 1
F5852-1E13-J574
Aquatech
3/8”JG
70
115V
W/CORD 0.6 GPM 1
Variable
Speed Pumps
Part No.
MFG.
FITTING
SHUT-OFF PRESSURE (PSI)
ELECTRICAL
NOTATIONS
CASE PK
F5853-GB12-V81D F5853-GE12-V81D F5502-IDN2-V77D
Aquatech Aquatech Aquatech
3/8”JG 3/8”JG
40 60 50
115V 115V 115V
W/CORD W/CORD W/CORD
1 1 1
3/8”ports*
PERFORMANCE DATA
DISCHARGE PRESSURE
PUMPHEAD
55 x 0
55 x 1
55 x 2
55 x 3
(PSI)
FLOW (GPM)
CURRENT (AMPS)
FLOW (GPM)
CURRENT (AMPS)
FLOW (GPM)
CURRENT (AMPS)
FLOW (GPM)
CURRENT (AMPS)
70 60 50 40 30 20 10
1.10 1.25 1.40 1.60 1.80 2.10 2.40 2.75
7.20 7.00 6.60 6.20 5.20 4.60 3.60 2.50
1.80 2.00 2.10 2.30 2.50 2.75 3.05 3.35
11.20 10.50
2.50 2.65 2.80 3.00 3.25 3.50 3.90 4.25
15.00 14.00 12.80 11.20
3.00 3.20 3.55 3.80 4.10 4.50 4.90 5.30
18.00 16.30 14.60 13.00 11.00
9.50 8.50 7.20 5.80 4.60 3.20
9.80 8.00 6.20 5.00
9.00 7.00 5.50
OPEN
119
WATER FILTRATION |
HOLIDAY HOUSE DISTRIBUTING
Made with FlippingBook - Online Brochure Maker